Section 2
5. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
Route Through Line Voltage Heyco
Attach to Contactor Terminals
NOTE: Three phase models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
Ice Machine Power
LuminIce™ Power
Part Number 000008463 Rev01 4/15
and
Incoming Power Supply
6. Route LuminIce™ hoses to evaporator and attach.
•
Insert hose closest to the control box in the bottom
evaporator bulkhead hole.
•
Insert the other hose in the upper evaporator
bulkhead hole.
7. Install the evaporator dust cover and test run the ice
machine and LuminIce™. The Luminice™ is
energized whenever power is applied to the ice
machine.
N
L1
Installation Instructions
9