Section 2
5. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
Route Through Line Voltage Heyco
Attach to Contactor Terminals
NOTE: Three phase models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
Ice Machine Power
LuminIce™ Power
Part Number 000008463 Rev01 4/15
and
Incoming Power Supply
6. Route LuminIce™ hoses to evaporator and attach.
Insert hose closest to the control box in the bottom
evaporator bulkhead hole.
Insert the other hose in the upper evaporator
bulkhead hole.
7. Install the evaporator dust cover and test run the ice
machine and LuminIce™. The Luminice™ is
energized whenever power is applied to the ice
machine.