Installation Instructions
LuminIce™ Installation U Models
!
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. Remove any ice from the bin, then remove bin to
allow easier access.
A. On the rear of the ice machine, remove 2
screws that secure the top cover, then remove
the top cover.
B. Remove two screws from the front grill, then pull
forward to remove grill.
C. Remove bin drain on left side of ice machine.
D. Rotate the latches on the left and right side of
the base to release the bin.
Rotate latch on left and right side and disconnect drain
E. Disconnect the control pad wiring on the right
side from the control box.
F. Slide the bin forward and remove.
12
Warning
3. Mount transformer on the left side with two screws.
NOTE: Clearance holes for mounting LuminIce™ are
factory installed. U0140 transformer mounts vertically.
All other models mount horizontally.
4. Route and secure line voltage wires (Black & White)
with the power cord. Wires must enter control box
through line voltage Heyco fitting and attach to L1
and L2 contactor terminals.
Part Number 000008463 Rev01 4/15