Télécharger Imprimer la page

Manitowoc LuminIce K00454 Manuel D'installation, D'utilisation Et D'entretien page 15

Publicité

Replacement Bulb Usage
Replacement bulbs are not interchangeable between
LuminIce™ and LuminIce II™.
LuminIce™ replacement bulb - K00425
LuminIce II™ replacement bulb - K00454
LUMINICE II™ INDICATOR LIGHTS
LuminIce II™ has an LED light for status indication:
Steady red light = Replace bulb
Flashing red light = Service is required
Blue = Normal operation
Red/Blue flash = Incorrect replacement bulb has
been installed.
Bulb Replacement Frequency
LuminIce™ and LuminIce II™ bulbs require replacement
on a yearly basis. Although the bulb will still illuminate
after 12 months, the effectiveness of the bulb diminishes
as operational hours increase. To retain maximum
effectiveness, replace the bulb on a 12 month schedule.
LuminIce II has an indicator light that will illuminate red
when the bulb needs replacement. A remote LED is
available as an accessory (K00455) to allow all
indicators (including the reminder) to be viewed without
removing the ice machine panels.
LuminIce™ Reminder Setup For Indigo
Model Ice Machines
Perform the procedure below to display a change-bulb
reminder every 12 months. Complete display panel
navigation is available in the Indigo™ ice machine
Installation Use and Care Manual. Publications for all
Manitowoc equipment are available on our website
www.manitowocice.com.
1. From the Set-Up menu, use the Down arrow to
highlight LuminIce™.
2. Press the Checkmark. On this screen, you can
choose to turn the reminder to AUTO or OFF by
highlighting your choice and pressing the
Checkmark. Selecting one will deselect the other.
3. When the check reflects your preference, use the
Down arrow to navigate to Exit and press the
Checkmark. The display will return to the Set-Up
menu.
Part Number 000008463 Rev01 4/15
Section 3
Customer Support
Bulb Replacement
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. Open the front door of the ice machine and then
remove the top panel.
3. Disconnect the power connector from the
LuminIce™ bulb.
4. Push bulb with finger and pull with other hand
toward the rear of the ice machine until bulb is free.
!
Warning
15

Publicité

loading