When closing.
Close the leaf. Fit the second stop against the opposite side of the arm and fasten it with the bolt.
Establishing the limit-switch points
With the gearmotor released and the gate-leaf closed, adjust the closing limit-switch grub screw by turning it
clockwise or counterclockwise. Tighten the nut to fasten the grub-screw.
Likewise, adjust the endstop by turning the endless screw on the other endstop.
+
-
-
+
-
+
-