GENERAL INSTALLATION INDICATIONS
Cable type and minimum thicknesses
Connection
Control panel power-supply
24 V DC gearmotor
Flashing light
Command and control devices
TX Photocells
RX photocells
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC) compliant;
whereas indoors, use H05VV-F-type cables that are 60227 IEC 53 (IEC) compliant. For power supplies up to
48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
To connect the antenna, use the RG58 (we suggest up to 5 m).
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual
power draw of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated
according to the actual power draw and distances. For connecting products that are not contemplated in this
manual, see the literature accompanying said products
INSTALLATION
Only skilled, qualifi ed staff must install this product.
⚠
The following illustrations are mere examples in that the space for fastening the operator and accessories
⚠
varies depending on the installation area. It is up to the fi tter, therefore, to choose the most suitable solution.
The following figures show a standard installation with the gearmotor and transmission arms fitted to
the left of the inward-opening gate. Installing the gear motor with right-hand drive arms, is symmetrical.
⚠ For outward opening gate leaves, follow the chapter titled "INSTALLING AND CONNECTING FOR
OUTWARD OPENING".
cable length
< 20 m
2
3G x 1.5 mm
3G x 2.5 mm
2
3 x 1.5 mm
2 x 0.5 mm
2 x 0.5 mm
2 x 0.5 mm
4 x 0.5 mm
20 < 30 m
2
2
3 x 2.5 mm
2
2
2
2