2. Adjust or replace the switch if necessary.
E14 LOAD DOOR NOT
FULLY CLOSED
•
Load door obstruction. Remove the obstruction and restart the press.
•
Load door full down switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch.
2. Adjust or replace the switch if necessary.
E16 EYE DID NOT
BLOCK
•
Cake is missing or stuck in can.
•
Belt is slipping or failed to run. Inspect the belt and repair as needed.
•
Discharge photoeye is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the photoeye.
2. Adjust or replace the photoeye if necessary.
E17 DISCHARGE DOOR
NOT FULLY OPEN
•
Dicharge door obstruction. Remove the obstruction and restart the press.
•
Discharge door up switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch.
2. Adjust or replace the switch if necessary.
E18 DISCHARGE DOOR
NOT FULLY CLOSED
•
Discharge door obstruction. Remove the obstruction and restart the press.
•
Discharge door down switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch.
Pellerin Milnor Corporation
Applies only to machines equipped with a load door. Indicates the
load door was not fully closed after the press attempted to lower
the load door. After correcting the problem, press
to automatic operation. This error may be caused by the following
conditions:
Indicates the cake did not block the photoeye when the press at-
tempted to discharge. The error clears automatically if the belt
eye input is made. This error may be caused by the following
conditions:
Indicates the discharge door did not fully open when the press at-
tempted to raise the door. The error clears automatically if the dis-
charge door up input is made. This error may be caused by the
following conditions:
Indicates the discharge door did not fully close when the press at-
tempted to lower the door. Pressing
door. Press
again to lower the door and return to automatic
mode. The error also clears automatically if the discharge door
down input is made. This error may be caused by the following
conditions: