Normal Operation
2.1.3
Starting the Press
Display or Action
Waiting for Can Full
Down
Waiting for Ram Full
Up
Waiting for Load
Chute Down
Waiting for Load Door
Down
Waiting for Discharge
Door Down
After the press initializes, the operator must confirm whether the press is loaded.
Does the PRESS have
a cake?
Figure 10. Cake Data Entry Window for Press
14
All emergency stop buttons must be unlatched and in the ready
position to allow machine operation.
/
Check that the machine master switch is at
Explanation
Energizes the press control circuit and silences the operator
alarm. Initialization begins.
Initialization begins with the controller driving the can to the full
down position.
With the can fully down, the controller lifts the ram to the full up
position.
If the machine is so equipped, the controller lowers the load
chute.
If the machine is equipped with a load door, the controller lowers
the load door.
The controller lowers the discharge door.
0
Enter 0 (No) if the press can is empty. The press control waits for
a signal from the Miltrac™ system that a load is in the press.
1
Enter 1 (Yes) if power to the press was interrupted with a load in
the can. The press control will prompt for the correct Miltrac™
data for the goods, as shown in
dow for Press, page 14
BNP1VO01.C04 0000579937 B.2 C.1 A.6 9/6/24, 8:18 AM Released
Figure 10: Cake Data Entry Win-
.
Pellerin Milnor Corporation