Presse à un niveau

Publicité

Display or Action
NOTE: The controller requires a delay of four seconds after commanding the ram down
before the ram can be commanded up.
3.1.6.2
Operating the Can
This function raises and lowers the can. The belt must be clear of goods when moving the can
down, and the scoop must be clear of goods when moving the can up.
Figure 19. Can Up/Down Screen
Display or Action
3.1.6.3
Running the Belt
This function opens the discharge door and runs the main belt forward and backward. The ram
must be above the Ram inside Can position, the can must be raised fully. The COINC runs when
the belt is commanded to run forward if the COINC eye is not blocked.
Figure 20. Run Belt Screen
Display or Action
Pellerin Milnor Corporation
Explanation
Raises the ram while driving the can down. The controller dis-
plays "Ram Full Up" when the Ram Full Up input is made.
Lowers the ram while driving the can down. The controller dis-
plays "Ram Full Down" when the Ram Full Down input is made.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
22).
Explanation
Raises the can by actuating the Can Up output if all safety condi-
tions are met. The controller displays "Can Full Up" when the
Can Full Up input is made.
Lowers the can by actuating the Can Down output if all safety
conditions are met. The controller displays "Can Full Down"
when the Can Full Down inputs are made.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
22).
Explanation
Automatically raises the discharge door and runs the main belt
forward by actuating the Belt Forward output if all safety
BNP1VO02.C09 0000580953 A.11 B.2 7/26/24, 11:50 AM Released