3.1.6.10
Cycling the Press
load can cause unnecessary wear on machine components.
Do not pressurize the ram without a load in the press unless necessary for
�
troubleshooting.
This function operates the press through a complete pressing cycle. Before the cycle begins, the
two Can Full Down inputs must be made and the load scoop must be clear of goods.
Figure 27. Cycle Press Screen
Display or Action
1. The ram descends past the Ram at Unload position, where it begins to pressurize.
2. The pump and proportional valves operate to pressurize the ram to the maximum pressure
based on the machine model.
3. Pressure is released.
4. The ram is raised until the Ram Full Up input is made.
5. The cycle repeats.
ENABLE RAM BREAK-IN?
0=N 1=Y
Pellerin Milnor Corporation
CAUTION: Machine Damage Hazards — Operating the press without a
Explanation
Starts the press cycle, as described below:
Stops the cycle.
Prompts to enable ram break-in.
NOTE: In normal operation the prefill valve is enabled
1 second after the press controller commands the ram
down. When ram break-in is enabled, this delay is ex-
tended to 20 seconds.
Enter 1 when the press is idle in this mode to enable Ram Break-
in, or enter 0 to disable the break-in feature.
If ram break-in is enabled, the user is prompted to re-enable ram
break-in every time the press control returns to automatic opera-
tion. This prompt does not appear if ram break-in is disabled.
Ram break-in is automatically disabled when press power is
turned off.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
BNP1VO02.C17 0000581031 A.11 B.2 7/26/24, 2:04 PM Released
22).
Manual Operation