3.1.6.6
Operating the Ram
This function raises and lowers the ram, and provides data used in testing and filling the press di-
aphragm. The belt and the scoop must both be clear of goods to lower the ram. Pump pressure is
not allowed to exceed 1500 psi while lowering the ram.
Figure 23. Ram Up/Down Screen
Display or Action
3.1.6.7
Operating the Discharge Door
This function raises and lowers the discharge door.
Figure 24. Discharge Door Screen
Display or Action
3.1.6.8
Pressurizing the Ram
This function pressurizes the ram. The scoop must be clear of goods and the can must be fully
down. Pump pressure is not allowed to exceed 1500 psi if the ram is above the Ram Inside Can
position.
Pellerin Milnor Corporation
Explanation
Raises the ram by actuating the Ram Up output if all safety condi-
tions are met. The controller displays "Ram Full Up" when the
Ram Full Up input is made.
Lowers the ram by actuating the Ram Down output if all safety
conditions are met. The controller displays "Ram Full Down"
when the Ram Full Down input is made.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
22).
Explanation
Opens the discharge door by actuating the Discharge Door Up
output.
Closes the discharge door by actuating the Discharge Door Down
output. The controller displays "Discharge Door Full Down"
when the Discharge Door Down input is made.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
22).
BNP1VO02.C13 0000581040 A.11 B.2 7/26/24, 1:57 PM Released
BNP1VO02.C14 0000581038 A.11 B.2 7/26/24, 1:58 PM Released
BNP1VO02.C15 0000581036 A.11 B.2 7/26/24, 2:01 PM Released
Manual Operation