Correcting Errors
E10 SCOOP BLOCKED
PRESS FAULT RECOVERY
E11 NO GOODS IN CAN
PRESS FAULT RECOVERY
•
The tunnel transferred an empty pocket which was not properly coded. Ensure that empty
pockets are properly coded in the tunnel.
•
Cake is undersized. Verify load size and adjust if necessary.
•
The tunnel is jammed. See instructions for clearing an obstruction in the tunnel in the tunnel
reference manual.
•
The ram full down switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the ram full down switch per "Setting Single Stage Press Proxim-
ity Switch Positions" in the service manual.
2. Adjust or replace the switch if necessary.
E12 RAM NOT AT
UNLOAD POSITION
•
Hydraulic oil pressure is low.
1. Check oil pipes for leaks and repair or replace as needed.
2. Verify that the hydraulic pump is working. Repair or replace as needed.
•
Ram at unload switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch per "Setting Single Stage Press Proximity Switch Posi-
tions" in the service manual.
2. Adjust or replace the switch, if necessary.
E13 LOAD DOOR NOT
FULLY OPEN
•
Load door obstruction. Remove the obstruction and restart the press
•
Load door full up switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the switch.
32
Indicates goods are laying on the load scoop. This usually occurs
when the goods are not wet enough to slide down the scoop. Use
the gaff hook to clear the scoop and press
matic operation.
Indicates the ram cleared the ram full down proximity switch
suggesting that there is no load in the can when the loading device
did not indicate an empty pocket. Pressing
and puts the press in manual mode. This error may be caused by
the following conditions:
Indicates the ram did not pass the unload point when the press at-
tempted to raise the ram. The error clears automatically if the ram
at unload input is made. This error may be caused by the follow-
ing conditions:
Applies only to machines equipped with a load door. Indicates the
load door was not fully open after the press attempted to raise the
load door. After correcting the problem, press
automatic operation. This error may be caused by the following
conditions:
to return to auto-
clears the error
to return to