Manual Operation
Figure 25. Pressurize Ram Screen
Display or Action
Pressure Transducer
PSI: xxxx
Proportional Valve
Counts: yyyy
3.1.6.9
Tracking the Belt
Keep hands and fingers away from gaps in and around the machine.
�
This function runs the belt forward to facilitate belt tracking and/or manual cake discharge. This
function starts only if the Can Full Up input is made.
1. The controller raises the ram to the full up position.
2. The discharge door begins opening when the Ram Inside Can input is made.
3. The belt begins running when the Ram Full Up input is made.
Figure 26. Track Belt Screen
Display or Action
26
Explanation
Drives the ram and can down.
Value xxxx displays the hydraulic pump pressure in pounds per
square inch.
Value yyyy displays the counts representing the opening of the
proportional valve. This value is 4095 while the ram is pressuriz-
ing, indicating that the proportional valve is fully open.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
WARNING: Closing gaps — can mutilate body parts.
Explanation
Starts the Track Belt function. The belt runs until commanded to
stop.
Stops the Track Belt function.
Exits this page and returns to the Press Functions menu screen
(Figure 17, page
22).
BNP1VO02.C16 0000581034 A.11 B.2 7/26/24, 2:03 PM Released
22).
Pellerin Milnor Corporation