Correcting Errors
Do not climb on press unless press power is locked out/tagged out.
�
4.1.1
Error Faults
Error faults are caused by mechanical or electrical malfunctions that cause inputs that should not
occur or a lack of inputs that should occur during press operation. When an error occurs, the dis-
play alternates between the normal automatic display and a brief description of the malfunction.
Read the safety manual before trying to correct any error and refer to the schematic and parts
drawings when necessary. These errors may be caused by failed input devices or output relays on
an input/output board or output board. Determine if the appropriate inputs or outputs are being
made using the instructions in the related section in document BICP1O01. If you are unable to
correct an error or determine the cause of the error from the information in this section, call your
dealer service technician or the Milnor
Display or Action
E01 CAN NOT FULLY
RAISED
1. Ensure proper actuation of the switch.
2. Adjust or replace the switch if necessary.
E02 CAN NOT FULLY
DOWN
•
Goods are under the can edge. Use the gaff hook to remove the goods or other obstruction
from under the can after manually raising the can.
•
Either or both can full down switches are malfunctioning or are out of adjustment.
1. Ensure the can is down.
2. Ensure proper actuation of the switches.
3. Adjust or replace the switches if necessary.
E03 RAM NOT FULLY
RAISED
•
Hydraulic oil pressure is low.
1. Check oil pipes for leaks and repair or replace as needed.
2. Verify that the hydraulic pump is operating. Repair or replace as needed.
•
Ram full up switch is malfunctioning or is out of adjustment.
1. Ensure proper actuation of the ram full up switch per "Setting Single Stage Press Proximity
Switch Positions" in the service manual.
30
®
factory for assistance.
Explanation
Indicates the can is not completely up. The error clears automati-
cally if the can full up input is made. Possible condition for this
error is that the can full up switch is malfunctioning or is out of
adjustment.
Indicates the can is not all the way down. The error clears auto-
matically if both can full down inputs are made. This error may
be caused by the following conditions:
Indicates the ram is not all the way up. The error clears automati-
cally if the ram full up input is made. This error may be caused
by the following conditions:
BNP1VT01.C02 0000581139 B.2 7/26/24, 2:54 PM Released
Pellerin Milnor Corporation