1 Controls
BNPUUO01 / 2023286
1.1
Single Stage Press Controls and Switches
1.1.1
Emergency Stop Switch (Locking Push Button)
One or more emergency stop switches
on the device. When pressed, any emergency stop switch removes power from the machine con-
trols, stops the machine and locks in the depressed (switch actuated, machine stopped) position.
When safe to do so, turn the button clockwise to unlock the switch. To resume operation, perform
the device's normal startup procedure.
Figure 1. Emergency Stop Switch
Stopped Position
NOTICE: Press the emergency stop switch immediately in an emergency situation.
This disables the 3-wire circuit while maintaining power to the microprocessor controller.
Display or Action
SHES
SHESR
4
BNPUUO01
(Figure 1: Emergency Stop Switch, page 4
Explanation
This symbol represents the emergency stop switch in Milnor
documents other than electrical wiring diagrams.
This notation in wiring diagrams refers to the emergency stop
switch on the main switch panel.
This notation in wiring diagrams refers to remote emergency
stop switches (those not located on the main switch panel).
0000579453
A.6
BNPUUO01.C01 0000579452 B.2 A.6 10/10/23, 2:29 PM Released
BNPUUO01.C02 0000579451 B.2 A.6 7/26/24, 3:49 PM Released
Run Position
7/19/23, 7:40 AM
Released
) are provided
®
Pellerin Milnor Corporation