13. Finally, for exceptional cases, the calibration values
obtained could be adjusted manually:
Set Vmot = 0.
Adjust VNmot based on the behavior of the
machine:
o If aspiration is activated unexpectedly, increase
VNmot in steps of 10 at a time.
o If the aspiration does not detect the utensil,
decrease VNmot in steps of 10 at a time.
It is recommended to periodically recalibrate the utensils
because their operation may be affected by changes in
environmental and electrical conditions.
Electrical noise may be excessive due to poor ground
connection.
FILTER DETECTION
The main screen continuously
shows an indicator of the filter fill
level.
If an error appears for no reason,
scan the code to access the
calibration tutorial
PROTECTIONS
If an obstruction occurs in the suction tube, or if the
filter is full, the suction will stop.
IMPORTANT
The full or clogged filter detection system has been
conceived as a protection for the motor of the suction
unit against possible eventualities. In no case should
you wait for the device to act before proceeding to
change the filter. Periodically check the fill level of
the filter-bag. (See section "Replacement of filters" of
this manual).
The suction unit also has a motor protection system that
disconnects it if it works continuously for more than 2
hours. This device is intended to prevent damage to the
motor in the event that, due to forgetfulness, the unit
remains in operation for too long a time. The equipment
will only allow vacuuming if we keep the machine on
for 15 minutes.
The rear power sockets allow devices to be connected up
to a maximum combined power of 400 W. If this power
is exceeded, the thermal switch (5) will act,
disconnecting the micromotor. If this circumstance
occurs, wait about 10 minutes before resetting the
thermal switch by pressing the button.
REPLACEMENT OF FILTERS
The EOLO INDUCTION suction unit has a filter circuit
in three stages: the first consists of a filter-bag; a second
stage with a cartridge-type absolute filter; and a third
stage assigned to a sheet filter located in the clean
chamber. This last filter has an unlimited duration, so it
should
only
be
changed
replacement is reserved for the Technical Service. To
clean and replace the filters we recommend:
Replacing the filter-bag:
1. Open the upper cover (D) of the suction unit by
acting on the latch (C). Remove the filter-bag
together with the cover of the suction chamber of the
machine. Carry out this operation very carefully to
prevent dust particles from falling into the suction
chamber of the appliance.
2. Present the new filter inside the suction chamber.
Make sure the filter fits over the squeegee ring (A),
and the filter base rests on the bottom tray of the vac
chamber.
3. Close the top cover of the machine again.
Replacing the cartridge filter:
1. Open the upper cover (D) of the suction unit by
acting on the latch (C), and remove it, together with
the filter-bag.
2. Loosen the screw holding the filter holder frame to
access the cartridge filter. Remove it carefully so that
no dust particles fall on the inlet of the vacuum motor
3. Place the new cartridge filter, and proceed to
assemble the rest of the components.
The cartridge filter cannot be recycled, so it always
requires its replacement. It is recommended to proceed
to the same every 1500 or 2000 hours of operation of
the machine.
occasionally,
and
its
15