9
OPERATION. CALIBRATION.
Power on the unit with "ON/OFF" (9) button. In case of low battery icon will
start flashing on the status bar.
Do the image calibration. Calibration levels background temperature of the
microbolometer and eliminates image flaws.ee calibration modes are
available: manual (M), semiautomatic (H) and automatic (А).
Manual (silent) calibration mode
Open the lens cap (1).
Press briefly the "ON/OFF" (9) button to power on the unit, hold down the
"MODE" (12) button for two seconds to enter the menu.
Use the navigation buttons "LEFT" (10) and "RIGHT" (11) to select item Cal.
Select mode M. Press "MODE" to confirm. To exit the menu, press and hold
"MODE" for two seconds or wait 10 seconds for automatic exit.
Close the lens cap. Press the "ON/OFF" button to calibrate. The image will
freeze for 1-2 seconds. Then open the lens cap. Calibration is completed.
If you see image flaws (such as frozen image, vertical stripes etc.) re-calibrate
the unit with the lens cap closed.
Semiautomatic calibration mode
Power on the unit, open the lens cap.
Hold down the "MODE" (12) button for two seconds to enter the menu.
Use the navigation buttons "LEFT" (10) and "RIGHT" (11) to select item Cal.
Select mode H. Press "MODE" to confirm.
Press the "ON/OFF" (9) button to calibrate. The image will freeze for 1-2
seconds and you will hear the sound of the internal shutter. Calibration is
completed.
Automatic calibration mode
In automatic calibration mode the thermal imager calibrates by itself according
to the software algorythm. The detector (microbolometer) is closed with the
shutter automatically. User assisted calibration with the "ON/OFF" button is
allowed in this mode.
Power on the unit, open the lens cap.
Hold down the "MODE" button for two seconds to enter the menu.
Use the navigation buttons "LEFT" (10) and "RIGHT" (11) to select item Cal.
Select mode A. Press MODE to confirm.
At the moment of the automatic calibration the image will freeze for 1-2
seconds and you will hear the sound of the internal shutter.
Note: time intervals between calibrations depend on the heat of the detector.
The unit may require calibration more frequently on activation.
Focusing and adjusting the image
Open the lens cap (1).
Adjust sharp image of icons on the status bar by turning the eyepiece diopter
adjustment ring (4).
To control display brightness, press briefly navigation buttons - "LEFT" (10)
(decrease) and "RIGHT" (11) (increase). Selected brightness level (from 0 to
20) appears next to icon
in the top right corner of the display.
10
To switch to contrast control, press briefly the "MODE" (12) button
(icon
appears). Press briefly navigation buttons - "LEFT" (10) (decrease)
and "RIGHT" (11) (increase) to select contrast level (from 0 to 20).
Corresponding contrast level appears next to icon in the top right corner of
the display.
Point the unit at a warm object located at a certain distance, 100 meters, for
example.
Rotate the lens focus knob (3) until you achieve quality image.
After this adjustment no further dioptre adjustment should be required,
regardless of distance or other factors. Adjust image quality only with the
lens focus knob.
Other functions
Press and hold down the "RIGHT" (11) button for two seconds to activate
2x digital zoom (available only if the unit is used as a monocular).
Icon
appears on the status bar.
Press and hold down the "LEFT" (10) button for two seconds to activate
colour inversion (functions "Hot white" and "Hot black"). When function
"White hot" is used, warm objects are represented in shades of bright
colour; "Black hot" represents objects in shades of dark colour.
Press and hold down "ON/OFF" (9) for two seconds to switch off the unit.
10
MENU
The menu includes options as follows:
Operating mode
Calibration mode
Brightness setting of menu icons
Clock setup
Remote control activation
Defective pixel repair
Status bar
The status bar shows information as follows:
Operating modes ("Rocks", "Forest", "Identification")
Calibration mode (manual, semiautomatic, automatic)
Digital zoom x2 activated
Color inversion activated
Clock setup
Battery status
Operating modes
The unit features three automatic operating modes: "Rocks"
contrast), "Forest"
(low contrast) and "Identification"
detail rendering).
Each mode includes optimal combination of parameters (brightness,
contrast, gain etc.) to deliver best possible image in specific viewing
conditions.
Press and hold down the "MODE" (12) button for two seconds to enter the
menu.
Press briefly "MODE" to confirm your choice.
Icon of the selected mode is shown on the status bar.
(enhanced
(improved
11