6
GUIDELINES FOR OPERATION
The unit has been designed for long-term use. To ensure sustainable
performance, please adhere to the following:
Before use make sure that you have mounted and adjusted the unit according
to the instructions of the section 8 "Operation".
Store with the lens cap on in the carrying case.
Switch off the unit after use.
Attempts to disassemble or repair the unit will void the warranty!
The unit is designed for use in various operating temperatures. However, if it
has been brought indoors from cold temperatures, do not turn it on for 2 to 3
hours. This will prevent external optical surfaces from condensation.
To ensure reliable performance, it is recommended to carry out regular
technical inspections of the unit.
WARNING! Do not point the objective lens of the unit at intense sources
of light such as the sun. This may disable electronic components of the
unit. The warranty does not cover damage caused by improper
operation.
7
BATTERY INSTALLATION
Turn the battery compartment knob (6)
counterclockwise until stop and remove it.
Install two CR123A batteries according to the
marking on the battery compartment cover and
inside it.
Turn the battery compartment knob clockwise
until stop – the latches from both sides of the
cover will pull out (see the drawing).
Replace the battery cover and press it until its
clicking position - make sure the cover is
closed on both sides.
Battery charge level is displayed on the status
bar (
).
In case of complete battery discharge, icon
flashing on the status bar.
Warning: do not use rechargeable batteries since their use causes
inaccurate battery level indication and and possible disconnection during
operation.
Note: please do not use batteries of different types or batteries with
various charge levels.
8
OPERATION
Unit CORE can be used as a monocular or front attachment for day device.
Original design allows the monocular to be quickly converted into attachment
and vice versa.
6
Open:
Close:
is
8.1. CORE as monocular.
Detailed description of the monocular CORE can be found in section
9 "OPERATION. CALIBRATION".
8.2. CORE as front attachment.
CORE as attachment is designed to use a day device both in the
nighttime and daytime in inclement weather (fog, smog, rain etc.).
To convert the monocular into attachment and to mount it on a day device,
please follow instructions as follows:
Stage 1. Mounting attachment's eyepiece on CORE unit.
Rotate the eyepiece locking ring (5) counterclockwise until you hear a
click and remove the eyepiece (Fig. 1).
Mount the
attachment's eyepiece
- Make sure that the salients (A) of the
located above the lower salients (see Fig.2).
- Locate the
attachment's eyepiece
Pulsar logo (L) on unit's body (Fig.3).
- Insert the
attachment's eyepiece
it by turning the b
ayonet-type ring
5
Fig.1
7
L
B
on the unit as follows:
attachment's eyepiece
are
so that the lock (B) is parallel to the
into unit's body until stop and secure
(7) clockwise.
wrong
correct
А
Fig.2
Fig.3
7