COMPONENTS
CONTROL PANEL COMPONENTS
1
10
4
Push-Button START/STOP: Push once to
1.
automatically start the engine. Push again to stop
the engine.
Battery Indicator: Indicates that power is ON. Light
2.
will remain illuminated while the unit is ON.
Battery Switch: Turns the battery ON and OFF. Must
3.
be ON before electric or remote start.
Low Idle: Low Idle minimizes fuel consumption,
4.
noise, and engine wear by lowering the engine RPM
during intermittent use. See LOW IDLE section for
important use considerations.
Fuel Selector Switch: Used to select gas or propane
5.
operation.
USB Ports: Two-port 5V/2.1A USB outlet. Accepts
6.
Type A USB plugs.
Data Center: Displays voltage, frequency, total
7.
hour meter, and run/maintenance timer.
Main Circuit Breaker: The main circuit breaker
8.
controls total output of all outlets to protect the
generator from overload or short circuit.
Smart Switch Outlet: Connects the Westinghouse
9.
ST Switch (sold separately) to the control panel.
10. Battery Charging Port: Used to charge the battery
with the included battery charger.
10 |
2
3
5
12
14
6
9
7 7
15
13
16
11. Ground Terminal: The ground terminal is used to
externally ground the generator.
12. 120/240-Volt AC, 50-Amp NEMA 14-50R
Receptacle: Receptacle can supply either 120V or
240V up to 50 amps.
13. 30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
L14-30R receptacle to 30 amps.
14. 120/240-Volt
Receptacle: Receptacle can supply either 120V or
240V up to 30 amps.
15. 30 Amp AC Circuit Breaker: Circuit breaker limit
the current that can be delivered through the NEMA
L5-30R receptacle to 30 amps.
16. 120-Volt AC, 30-Amp NEMA L5-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
17. 20 Amp AC Circuit Breakers: Circuit breakers
limit the current that can be delivered through
each NEMA 5-20R receptacle to 20 Amps.
18. 120-Volt AC,
Receptacles: Each receptacle is capable of
carrying a maximum of 20 amps on a single
receptacle or a combination of both receptacles.
8
18
11
AC,
30-Amp
NEMA
20-Amp
NEMA 5-20R
17
L14-30R
GFCI