Installation
4.1.2 Load hooks and lifting tackle
The device is attached to the carrier/lifting device with a load hook or a suitable lifting tackle.
Ensure that the single chains strands are not twisted or knotted.
Attaching the device to the lifting device/carrier, take care that all local safety regulation is observed.
4.2
Hydraulical connection
To operate the VZ-HS device, a hydraulic circuit is required to open and close the clamp. The
hydraulic hoses on the carrier device are connected to the connections on the control block of the
VZ-HS device.
If the VZ-HS device is equipped with a rotary motor, a second control circuit is required.
A pilot-operated non-return valve is installed in the hydraulic circuit of the VZ-HS device to prevent
the load from falling out of the tongs in the event of a pressure drop.
If the carrier device does not have the required number of hydraulic circuits, a control circuit can be
used to connect two functions via an electromagnetic changeover valve (ELMV)
When connecting, make sure that the hydraulic hoses do not have any chafing points and cannot
get caught on any protruding edges during lifting and lowering movements.
G
To ensure that the device (VZ-HS) functions correctly and reliably, the following values must be
observed:
Connected loads::
Conveying capacity
Carrier device:
Operating pressure
Carrier device:
Back pressure
in the return flow:
To avoid faults and malfunctions, the correct connection of the hydraulic hoses must be
checked before each start-up of the device (VZ-HS)!
51600014
optimal
25 in l/min
200 bar
0 bar
15 / 23
minimal
15 in l/min
200 bar
0 bar
maximum
75 in l/min
250 bar
5 bar