Pour vérifier la configuration d'une instance de routage SCSI, formulez les
commandes suivantes :
1. enable — Cette commande active le mode Administrateur.
2. Show scsirouter zeus — Cette commande fait apparaître les
Exemple 8 : Vérification de la configuration d'une instance de routage SCSI
[SR2122]# show scsirouter zeus
zeus description "(not set)"
zeus authenticate "none"
zeus primary "none"
zeus proxy server disabled
zeus failover primary "none"
zeus failover secondary "none"
zeus target naming authority "none"
zeus target log level is not available
zeus target chimaera_apps description "(not set)"
zeus target chimaera_apps Name "iqn.1987-05.com.hp.00.d3f8a650c7deacecd97e1812d.chimaera_"
zeus target chimaera_apps enabled "TRUE"
zeus target chimaera_apps accesslist "all"
zeus target chimaera_apps lun 24 wwpn "22:00:00:20:37:19:15:05" lun "0" I/F fci1
zeus target chimaera_eng description "(not set)"
zeus target chimaera_eng enabled "TRUE"
zeus target chimaera_eng accesslist "all"
zeus target chimaera_eng lun 17 lunwwn "22:00:00:20:37:19:12:9d" I/F fci1
zeus target pegasus_web description "(not set)"
zeus target pegasus_web Name
"iqn.1987-05.com.hp.00.d6bf2b11ed9c88ce9299ea3f0961ad94.pegasus_web"
zeus target pegasus_web enabled "TRUE"
zeus target pegasus_web accesslist "all"
zeus target pegasus_web lun 3 serial "LS0932210000019451JM5" I/F fci1
Manuel de l'utilisateur du routeur de stockage iSCSI hp StorageWorks 2122
paramètres configurés pour l'instance de routage SCSI nommée zeus
(Exemple
8).
Configuration du routage SCSI
111