Voltage versions and electrical data
Connection of electrically heated variant
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Mains connection cable, min. cross-section
Cable gland
Connection variant with reduced heater rating
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Mains connection cable, min. cross-section
Cable gland
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock in accordance with
IEC 60309 and IEC 60947 so that electrical safety checks can be carried out easily.
For hard-wired machines, an isolator in accordance with IEC 60947 must be installed.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are sensit-
ive to universal current (type B).
Plumbing
Cold water connection
Required flow pressure
Maximum flow rate (if no hot water and hard water supply)
Maximum flow rate
Maximum flow rate without detergent drawer (if no hot water and hard water supply)
Maximum flow rate without detergent drawer
Threaded union required (male thread, to be provided on site in accordance with DIN 44991,
flat sealing)
Length of water inlet hose included in scope of supply
Length of the water inlet hose included in scope of supply without detergent drawer
*With liquid dispensing
Hot water connection
Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Maximum flow rate without detergent drawer
Threaded union required (male thread, to be provided on site in accordance with DIN 44991,
flat sealing)
Length of water inlet hose included in scope of supply
*With liquid dispensing
en - Technical data
3N AC 380-415 V
50 - 60 Hz
5 x 16 mm²
M40 x 1,5 mm
3N AC 380-415 V
50 - 60 Hz
5 x 1,5 mm²
M16 x 1,5 mm
100–1000 kPa (1–10 bar)
74 (79,5*) l/min
26 (31,5*) l/min
72 (77,5*) l/min
20 (25,5*) l/min
2 (3*) x 1550 mm
1 (2*) x 1550 mm
100–1000 kPa (1–10 bar)
20 (25,5*) l/min
1 x 1550 mm
31 kW
3 x 63 A
10,1 kW
3 x 20 A
3/4"
60 °C
16 l/min
3/4"
39