Water connection
for variants with
reduced heater
rating (RH)
The appliance should be connected to cold and hot water supplies. A
minimum hot water temperature of 80 °C is recommended in order to
use all programmes. Lower temperatures may result in longer pro-
gramme running times or cause programmes to be interrupted. Water
inlet temperatures below 60 °C are not permitted, as they can lead to
significantly longer programme running times.
Dispenser pump connections
Up to 12 dispenser pumps can be connected to the washing machine.
Dispenser pump connections on the back of the machine
Connections 1 and 2 are provided for viscous agents can also be used
for high pressure dispensing systems with water injection. The dis-
pensing systems must be fitted with a separate drinking water safety
mechanism in accordance with EN 61770 and EN 1717. The maximum
flow rate is 1500 ml/min with a maximum flow pressure of 300 kPa.
These connectors are sealed and need to be drilled open using a
8 mm drill bit before connecting.
Make sure that you only drill through the first panel (I) as there is a
deflecting panel (II) 10 mm behind it.
Connections 3 to 12 are provided for liquid detergent. High pressure
dispensing systems with water injection must not be connected to
these connections. The connectors are sealed and must be cut to the
diameter of the hose with a small saw before they are connected.
If opened connectors are no longer required, they must be resealed
using a suitable sealant (e.g. silicone).
Connection terminals for five time-controlled dispenser pumps, which
can be operated without a multifunction module, are located behind
the cover adjacent to the electrical connection.
en - Installation notes
29