5.2.2 Lock/unlock (Set up 551)
Allows the locking of the panel controls and the insertion of a protection code.
551.
60
Control panel functions
The carrying out of any operation on a locked control panel causes a special screen to appear.
Access the panel functionalities temporarily (5 minutes) by rotating the encoder and entering the correct password.
Confirm the operation by pressing the encoder key.
Unlock the control panel definitively by entering set-up (follow the instructions given above) and bring back parameter 551 to
"0".
Confirm the operation by pressing the encoder key.
To exit the set-up, go to parameter "0." (save and quit) and press encoder key.
5.2.3 Circuit resistance calibration (set up 705)
705.
705.
10.0
Parameter selection
Select the required parameter (551.).
Set a numerical code (password) by rotating the encoder.
Confirm the operation by pressing the encoder key.
To exit the set-up, go to parameter "0." (save and quit) and press encoder key.
Parameter selection
Select the required parameter (705.).
Calibration
Remove the cap to put the nozzle holder tip of the exposed torch. (MIG/MAG)
Place the tip of the wire guide in electrical contact with the work piece. (MIG/MAG)
Place the electrode holder torch and the piece to be welded into contact. (MMA)
Press the
Maintain contact for at least one second.
Confirm the operation by pressing the encoder key.
To quit the "adjustment" section, press the encoder again.
When the operation ends, the system returns the display to the parameter entry
screen.
To exit the set-up, go to parameter "0." (save and quit) and press encoder key.