Connect the gas hose from the cylinder to the rear gas connection. Adjust the gas flow from 5 to 15 l/min.
Connect the earth clamp to the negative socket (-) of the power source. Insert the plug and turn clockwise until all parts are
secured.
Motor compartment
Open the right side cover.
Check that the roller groove is consistent with the diameter of the wire you wish to use.
Unscrew the ring nut from the spindle and insert the wire spool.
Insert also the spool pin, insert the spool, reposition the ring nut and adjust the friction screw.
Release the rolls lever of the wire feeder , sliding the end of the wire into the wire guide bush and, passing it over the roller, into
Connect the gas hose from the cylinder to the rear gas connection. Adjust the gas flow from 10 to 30 l/min.
Earth clamp connector
1
Negative power socket (-)
2
Ring nut
1
Friction screw
2
Rolls lever
3