EQUIPMENT USE
4. EQUIPMENT USE
EN
When switched on, the system performs a series of self-tests to verify its own correct functioning and that of the devices
connected to it. At this stage the gas test is also carried out to check the proper connection to the gas supply system.
Refer to the "Front control panel" and "Setup" sections.
5. SETUP
5.1 Parameter set up and setting
Permits set-up and adjustment of a series of additional parameters for improved and more accurate control of the welding
system.
The parameters present at set up are organised in relation to the welding process selected and have a numerical code.
Entry to set up
0.
Selection and adjustment of the required parameter
Rotate the encoder until you display the numerical code for the required parameter.
This parameter is identified by the "." to the right of the number.
If the encoder key is pressed at this point, the value set for the parameter selected can be displayed and adjusted.
The entry into the parameter submenu is confirmed with the disappearance of the "." to the right of the number
Exit from set up
To quit the "adjustment" section, press the encoder again.
To exit the set-up, go to parameter "0" (save and quit) and press encoder key.
5.1.1 List of set up parameters (MMA)
0
Save and Exit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default values.
3
Hot start
Allows adjustment of the hot start value in MMA.
Permits an adjustable hot start in the arc striking phases,facilitating the start operations.
Basic electrode
Minimum
0/off
CrNi electrode
Minimum
0/off
Cast Iron electrode
Minimum
0/off
The central zero on the 7-segment display confirms entry.
Maximum
Default
500%
80%
Maximum
Default
500%
100%
Maximum
Default
500%
100%
Cellulosic electrode
Minimum
Maximum
0/off
500%
Aluminum electrode
Minimum
Maximum
0/off
500%
Rutile electrode
Minimum
Maximum
0/off
500%
22
Default
150%
Default
120%
Default
80%