1
Allows you to reset all the parameters to the default values.
Wire speed
3
Allows the regulation of the wire feed rate.
Minimum
Maximum
0.5 m/min
22.0 m/min
4
Current
Smart
Allows the regulation of the welding current.
Minimum
Maximum
3 A
Imax
5
Workpiece thickness
Allows the thickness of the part being welded to be set.
6
Corner bead "a"
Lets you set bead depth in a corner joint.
7
Voltage - Arc length
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Synergic mode
S
Smart
Minimum
Maximum
-5.0
+5.0
Manual mode
Minimum
Maximum
5.0 V
55.5 V
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking of the arc.
Permits filling of the torch with gas and preparation of the environment for welding.
Minimum
Maximum
0/off
99.9 s
11
Permits adjustment of the wire feed speed in the phases prior to arc striking.
Minimum
Maximum
10 %
100 %
12
Motor slope
Allows you to set a gradual transition between the sparking wire speed and the welding wire speed.
Minimum
Maximum
0/off
1.0 s
15
Burn back
Permits adjustment of the wire burn time, preventing sticking at the end of welding.
Permits adjustment of the length. Permits adjustment of the length of the piece of wire outside the torch.
Minimum
Maximum
-2.00
+2.00
Default
-
Smart
Smart
Default
0/syn
Default
5.0 V
Default
0.1 s
Default
50 %
Default
0/off
Default
0/syn
25