INSTALLATION
Welding polarity change
This device permits welding of any welding wire on the market thanks to the easy selection of the welding polarity (direct or
EN
reverse).
Reverse polarity: the power cable from the torch must be connected to the positive pole (+) of the terminal strip. The power cable
from the earth socket must be connected to the negative pole (-) of the terminal strip.
Direct polarity: the power cable from the torch must be connected to the negative pole (-) of the terminal strip. The power cable
from the earth socket must be connected to the positive pole (+) of the terminal strip.
Before shipment, the equipment is set for use with reverse polarity!
Power cable
1
Positive power socket (+)
2
Earth clamp connector
3
Negative power socket (-)
4
Power cable
1
Negative power socket (-)
2
Earth clamp connector
3
Positive power socket (+)
4