the set temperature value.
In the Fahrenheit display mode: When the temperature measured by the
temperature probe is within ± 2 ° F of the set temperature, the temperature
display will display the set temperature value
Error code
LL: When the temperature measured by the temperature probe is lower than 0
degrees Celsius, "LL" is displayed, flashing, and the cooling is stopped
When the temperature probe is short-circuited or disconnected, the setting
temperature value is displayed, the compressor will work for 15 minutes and stop
for 18 minutes.
When the temperature measured by the temperature probe is higher than 37
degrees Celsius,the setting temperature value is displayed,the compressor will
work for 15 minutes and stop for 18 minutes.
Forced defrosting function
When the compressor works for 12 hours, the compressor will stop working for 30
minutes.
Memory function
The control board is re-energized after each power-off, the temperature setting
value, Fahrenheit/Celsius state will be the same as before the power-off, and the
length of power-off time is not limited.
30