HOW TO CLEAR DATA
Clear: Single clear and total clear:
Single clear: Clear last weighing data.
Total clear: Clear all weighing data.
Step 1: Press"-"
Display: CLL  1
Step 2: Press "∧" or "∨"
Convert last bit between 1 and 2
1 --- Single clear
2 --- Total clear
Step 3: Choose single clear or total clear
press"OK" to confirm.
Attention:
No data in memory, press"-", instrument displays "no".
When display clear interface, press "C" to exit clear state.
SPECIFICATIONS
Interval Value: 1/2/5/10/20/50
Load cell excitation: DC 5V
Battery: 4.8V/3.2AH nickel-hydrogen batteries, use for approximately 40 hours without charging
Environment temperature: Scale body -10⁰C~40⁰C; Instrument 0⁰C~40⁰C
Maximum wireless transceiver distance: 200 m (open area)
Radio frequency: 433MHz
LOW POWER SYMBOL OF BATTERIES
When hand-held display is in process of normal weighing, it will show "L" at the left of the display.
L * * * *
Indicates transmitter batteries are in low power, need to be recharged.
The device can be used for another 30 minutes after low power, then the transmitter shuts down automatically.
BATTERY SAFETY POINTS
EN
When using the remote please follow the tips for use. This device is powered by a rechargeable battery. 
When the battery is new, please discharge it by using the device normally. After that, fully charge the battery. For best 
performance of the battery please do so two to three times. If you want to use the battery for a long time, you have to 
charge it before it completely runs out of energy.
Protect battery from water and short circuit as it will damage the battery.
If the connectors of the battery are being short circuited so the battery will be damaged.
CHARGER USE
3 indication states of charger:
Power on 230V, indicator light is green.
In charging, indicator light is red.
Charging full, indicator light is green.
CHARGING INDICATOR
Charging indicator of hand-held display
When the "low-power" symbol is shown on hand-held display, the device needs to be charged. Please do so immediately.
When the symbol of "low power" lights up, the instrument can be used for another 30 minutes. After that it will shut down 
automatically.
CHARGING METHOD OF HAND-HELD DISPLAY
Please use charger along with the scale, using other chargers may cause damage to the instrument and battery.
Batteries take 5-7 hours to be fully charged. After being fully charged, the charger will automatically turn into small flow 
state.
14
8. INSTRUCTION OF INFRARED CONTROLLER
Remote control & usage is the same with the scale body buttons. The controller is powered by AAA battery.
15