6 .3

Storage

Prior to the storage of the hammer in the original case
release the impact as during a measurement and fix the
plunger (1) with the push-button (6). Secure the push-
button additionally with a strong adhesive tape.
• Store the concrete tester and accessories in the origi-
nal case in a clean, dust-free room.
• If the unit is not used for a long period of time, remove
the batteries.
6 .4

Maintenance

We recommend to check the concrete test hammer
for wear after 2 years at most and clean it. Do this as
described below.
The concrete test hammer can either be sent
to a service center authorized by the vendor or
else it can be maintained by the operator
according to the following description.
The items in (brackets) are illustrated in Fig. 6.2,
"Longitudinal section through the concrete test hammer".
© 2017 Proceq SA
6 .4 .1

Stripping Down

Warning!
Never strip down, adjust or clean the slider
and guide rod (4) (see Fig. 6.2), otherwise
the slider friction may change.
Special tools are required to readjust it.
• Position the concrete test hammer perpendicular to the
surface.
Danger!
The impact plunger (1) generates a recoil
when it deploys. Therefore always hold the
concrete test hammer with both hands!
Always direct the impact plunger (1)
against a hard surface!
• Deploy the impact plunger (1) by pushing the concrete
test hammer towards the surface until the push
button (6) springs out.
• Unscrew the cap (9) and remove the two-part ring (10).
• Unscrew the rear cover (11) and remove the compres-
sion spring (12).
• Press the pawl (13) and pull the system vertically up
and out of the housing (3).
• Lightly strike the impact plunger (1) with the hammer
mass (14) to release the impact plunger (1) from the ham-
mer guide bar (7). The retaining spring (15) comes free.
Maintenance and Care
17