UK | 6 Requirements at the installation site
6 Requirements at the installation
site
● Ambient temperature - 15 °C to + 40 °C.
● Airstream temperature max. 40 °C.
● Max. permissible humidity in installation
room PP 45: 70 % / PPB 30: 90 % (at 20 °C).
● A level and solid wall surface is needed for
wall installations.
NOTICE
Conveyance of structure-borne sound if
core drill hole touches door/window lintels
or ring beams. Observe spacing between
core drill hole and door/window lintels and
ring beams.
● External wall with sufficient load-bearing
capacity (min. 200 kg/m³).
● For filter changes, ensure sufficient space to
work in front of the unit.
● Do not drill core drill hole for unit assembly
and do not drill fixing points on external and
internal covers in load-bearing components,
such as in the lintel or ring beam.
7 Technical data
7.1 Technical data for PP 45
External diameter
Wall sleeve max. length 500 or 800 mm
Wall thickness min.
max.
Air filter outside
Air filter inside
Air volume/unit
Protection class /
degree of protection
Sound pressure level, at
distance of 1 m condi-
tions without obstructions
(ventilation level 1 to 5)
Rated voltage/
power frequency
Volumetric flows for ven-
tilation levels 1, 2, 3, 4, 5
28
Ø 160
265 mm
490 / 790 mm
G3
G2
42 m³/h
IP 00 / 2
23 / 28 / 33 /
37 / 40 dB(A)
230 V
50/60 Hz
15 / 20 / 30 /
36 / 42 m³/h
Power consumption
Permissible ducting
lengths with wired
connection
Radio components:
Frequency range (in
acc. with EN 300220-1)
"Wireless" operating
distances in the building
are dependant on the
building materials used:
●
DS 45 RC PP 45 RC
●
PP 45 EO PP 45 RC
●
PP 45 RC PP 45 RC
With PP 45 RC as
●
signal booster
7.2 Technical data for PPB 30
External diameter
Wall sleeve
(max. length)
Wall thickness
Air filter inside
Air volume/unit
in exhaust air mode
Degree of protection
Sound pressure level, at
distance of 1 m condi-
tions without obstructions
(ventilation level 1 to 5)
Rated voltage/
power frequency
Volumetric flow heat re-
covery mode ventilation
level 1 to 5
Volumetric flow
exhaust air mode
Power consumption
(ventilation level 1 to 5)
Degree of heat provision 72 - 73 % (level 3)
SPI
SEC value
Permissible ducting
lengths with wired
connection
Weight slide-in module cpl. 3.6 kg
1.2 / 1.7 / 2.1 /
2.8 / 3.5 W
From star point max.
25 m per ventilation
unit
868.35 MHz
up to:
30 m
30 m
30 m
40 m
Ø 160
PP 45 RHK: 500 mm
PP 45 RHL 800 mm
320 - 790 mm
2x G3
45 m³/h
IP X4
18 / 32 / 41 /
45 / 49 dB(A)
230 V
50/60 Hz
5 / 12 / 18 /
22 / 26 m³/h
45 m³/h
1.7 / 2.5 / 3.4 /
4.4 / 5.3 W
0.19 W / (m³/h)
A (-39.41)
From star point max.
25 m per ventilation unit