The following configurations are possible de-
pending on the local regulations in force:
• Fig. 16: external air intake (C) ducted as far as
the firebox (D). Lower grille (A) supplied for the
recirculation of ambient air on the cladding.
C
A
The image is purely indicative.
• Fig. 17: air intake (F) on the cladding, ducted as
far as the firebox (D). Lower grille (A) provided
in the cladding and external air intake (B) for
the recirculation of ambient air.
B
F
The image is purely indicative.
64
• Fig. 18: lower grille (A) provided in the cladding
and external air intake (B) for the recirculation
of ambient air to be created inside or outside
the cladding.
E
D
The image is purely indicative.
Fig. 16
6.4.2 Combustion air inlet pipe
It is possible to use a combustion air pipe behind
the machine with a pipe diameter of 80 mm and
a maximum length of 4 m, equivalent for external
direct connection.
If the "COMBUSTION AIR DUCTING KIT" accessory
is not used, when installation is complete, make
E
sure that the hose used can slide appropriately
when the moving part of the appliance is pulled
out and inserted.
D
A
Fig. 17
B
A
Max 4 mt.