4-1. Controls (3080 Models)
1
8
1
Gas/Air Pressure Gauge
2
Gas/Air Pressure Adjustment Knob
3
Output Control
Use control to set cutting output.
Gas/air automatically flows at the set
pressure.
Use Gas/Air Set area of control range for set-
ting gas/air pressure (see Section 4-3).
4
Trouble Lights (see Section 5-2)
SECTION 4 – OPERATION
2
9
Rear of
Unit
Power light comes On when Power switch is
placed in On position.
5
Power Light
6
Ready Light
Ready light comes On when unit is On to indi-
cate that all safety shutdown systems are
okay. If Ready light does not come On, check
trouble lights.
7
Trigger Hold Switch
To cut without holding torch trigger, set trigger
hold switch so upper end is pressed In. Press
5
6
7
10
the torch trigger, begin cutting, and release
the trigger. To stop cutting, press and release
trigger.
When set in down position, trigger must be
held closed while cutting.
8
Torch Quick-Disconnect Connector
9
Power Switch
10 Door for Consumables Storage
3
4
Ref. 187 861-B / Ref. 802 201