8.5. DeviceNet (MSC CE-DN)
8.5.1. Process data mapping
8.5.1.1.
Assembly instance 96h (Consuming Instance)
Byte offset
Size
0
USINT
1
USINT
2
USINT
3
USINT
8.5.1.2.
Assembly instance 64h (Producing Instance)
Byte offset
Size
0
USINT
1
USINT
2
USINT
3
USINT
4
USINT
5
USINT
6
USINT
7
USINT
8
USINT
9
USINT
10
USINT
11
USINT
12
USINT
13
USINT
14
USINT
15
USINT
16
USINT
17
USINT
18
USINT
19
USINT
20
USINT
21
USINT
8.5.2. Explicit messaging
To access Errors data, Input diagnostics, OSSD diagnostic and Project CRC the service 0x0E (Get attribute single) shall be
used.
Name
Fieldbus inputs
System I/O
Analog data
Errors data CPU 0
Errors data CPU 1
Input diagnostics
OSSD diagnostics
Project CRC
1
See 8.10. Acyclic data format for more information.
2121341-09-12/23 (trad. mode d'emploi d'origine)
Mode d'emploi CONTRÔLEUR INTÉGRÉ DE SÉCURITÉ MODULAIRE MSC
Name
Fieldbus input byte 0
Fieldbus input byte 1
Fieldbus input byte 2
Fieldbus input byte 3
Name
System status
Reserved
Input status byte 0
Input status byte 1
Input status byte 2
Input status byte 3
Input status byte 4
Input status byte 5
Input status byte 6
Input status byte 7
Input status byte 8
Input status byte 9
Input status byte 10
Input status byte 11
Input status byte 12
Input status byte 13
Input status byte 14
Input status byte 15
Fieldbus input byte 0 feedback
Fieldbus input byte 1 feedback
Fieldbus input byte 2 feedback
Fieldbus input byte 3 feedback
1
Class
Instance
A2h
101h
A2h
01h
A2h
204h
A2h
03h
A2h
04h
A2h
05h
A2h
06h
A2h
07h
MODULES DE BUS DE TERRAIN CE-... MSC
Byte offset
Size
22
USINT
23
USINT
24
USINT
25
USINT
26
USINT
27
USINT
28
USINT
29
USINT
30
REAL
34
REAL
38
REAL
42
REAL
46
REAL
50
REAL
54
REAL
58
REAL
62
REAL
66
REAL
70
REAL
74
REAL
78
REAL
82
REAL
86
REAL
90
REAL
Attribute
Length (byte)
05h
4
05h
30
05h
64
05h
9
05h
9
05h
32
05h
32
05h
2
Name
Probe status byte 0
Probe status byte 1
Probe status byte 2
Probe status byte 3
OSSD status byte 0
OSSD status byte 1
OSSD status byte 2
OSSD status byte 3
Analog data float 0
Analog data float 1
Analog data float 2
Analog data float 3
Analog data float 4
Analog data float 5
Analog data float 6
Analog data float 7
Analog data float 8
Analog data float 9
Analog data float 10
Analog data float 11
Analog data float 12
Analog data float 13
Analog data float 14
Analog data float 15
Access type
Set/Get
Get
Get
Get
Get
Get
Get
Get
FR