Error messages displayed on the control unit:
MESSAGE
P1
P2
If one or more error codes are displayed, write them down, turn off the appliance then turn it back
on after 3-4 minutes. If one or more of the codes are again displayed, contact the dealer to request
technical support and inform them of the error codes.
Food storage
The following instructions should be followed in order for the appliance to perform at its best:
Put the food into the appliance after it has reached the desired temperature displayed on the
control unit. To avoid restricting air circulation, do not put too many products in the upper part
of the refrigerator;
Do not place hot foods inside the appliance (they must be previously cooled in a blast chiller)
or in unclosed containers. Always package and protect foods before putting them in the refrig-
erator;
Avoid opening and door frequently and for prolonged periods of time, and wait at least 30
seconds before re-opening the door.
Defrosting - Defrost timing (see Pic.3 - Section 8)
The control unit automatically performs 4 defrost cycles in a 24 hour period (once every 6 hours).
When the defrost cycle is active, the D
begins from the moment the appliance was last turned on. To perform a manual defrost cycle, just
press the D
button (D
EFROST
finished, the defrost timer will reset itself so that no defrost cycles will be performed for the next 6
hours. During manual defrost, the defrost light on the display will be on. The defrost water evapo-
ration is automatic on all models.
ATTENTION!
Precautions for use
To reduce cooling losses, do not open the door too often and keep it open as little as possible;
Do not cover the top of the appliance. The air must be able to circulate to properly cool the
compressor and also to evaporate the defrost water;
The food products must be placed at a sufficient distance from one another. Cooling is limited
if there is very little distance between products;
The height of the racks must be chosen based on the height of the food products;
If hot meals are to be stored, let them completely cool down before placing them inside the
appliance. Putting hot food or drinks inside the appliance creates an excessive amount of steam
which can cause anomalies and malfunctions;
In the event of a power failure, if possible, do not open the door to prevent cool air from escaping;
Wait at least 2-3 minutes after disconnecting the plug before connecting the appliance to the
power supply line again.
TRANSLATION OF THE ITALIAN ORIGINAL INSTRUCTIONS
ERROR DESCRIPTION
Faulty thermostat probe
Faulty evaporator probe
EFROST
) for 3 seconds and a defrost cycle will immediately begin. When
EFROST
EFFECT
The temperature is no longer be-
ing adjusted correctly.
The duration of each defrost cy-
cle will be exactly 20 minutes.
LED on the control unit (Led nr.1) remains on. The timer
SOLUTION
Contact the dealer
Contact the dealer
- 27 -