Food products must only be placed inside the appliance after they have been previously refrig-
erated and have reached the storage temperature;
Food products should only be placed inside the appliance if they are packaged or closed in
suitable food-grade containers.
Each support rack has a maximum capacity of 25 kg; the appliance must not exceed a total load
of 125 kg for all AKT690 models, and 200 kg for all AKT1490 models.
5.4 Operation
The appliance is operated by means of the main O
which is used to set the desired operating temperature.
See Section 8 for more details about the control panel.
The user may carry out the following operations:
Switch on/off (see Pic.1 and Pic.3 - Section 8)
Press the O
/O
switch: the current temperature inside the refrigerator will appear on the display.
N
FF
After about 3 minutes, the compressor on LED (Led nr.2) and, in BT models, the internal fan on LED
(Led nr.3) will turn on. In the case of a power failure, the compressor will restart approximately 3
minutes after the power supply has been restored in order to avoid damaging the appliance by
switching it on and off multiple times.
The internal light automatically turns on when the door is opened and turns off when it is closed,
except the TNG and BTG models which have a manual lighting on/off button.
To shut off the appliance, press the O
plug from the electrical socket. Wait at least 10 seconds after disconnecting the plug before con-
necting the appliance to the power supply line again.
Temperature setting (set point)
The temperature setting can be read by pressing the S
Proceed as follows to change the temperature setting:
Press and hold the S
Press the ▲(U
perature, respectively, until the new temperature has been reached;
Confirm the new setting by pressing the S
ous operation. The newly set value will flash for 2 seconds to indicate the confirmation and
storage of the new data. The data is stored, even if no key is pressed for 15 seconds.
When running, the appliance will cool the cell until the currently set operating
temperature is reached. Once the set operating temperature is reached, the elec-
tronic control unit will turn off the cooling unit until the temperature detected by
the probe rises by about 4-5 degrees. When this happens, the control unit will
turn on the cooling unit to lower the temperature until it returns to the set oper-
ating temperature.
This "on-off" mechanism is perfectly normal and is common in all refrigeration
equipment such as refrigerated bars, cabinets, display cases, etc.
Please note that the temperature shown on the control unit display refers to the
air temperature (very susceptible to temperature changes due to the opening of
the door) and not to the temperature at the core of the appliance, which is much
more constant over time.
- 26 -
N
button until the " °C " symbol flashes;
ET
) or ▼(D
) button within 15 seconds to increase or decrease the set tem-
P
OWN
/O
power switch and the digital control unit
N
FF
/O
button on the control panel and then disconnect the
FF
button once.
ET
button within 10 seconds of completing the previ-
ET
TRANSLATION OF THE ITALIAN ORIGINAL INSTRUCTIONS