Hotwire Anemometer / English
Performing a mean calculation in time
• Press "Mean" for 2 seconds.
• Mean
is lit. The elapsed measuring time (mm:ss) is displayed in the upper line, While the current
reading is displayed in the lower line.
• To change between displaying the temperature, flow velocity and calculated volumetric flow rate: Press
"Flow/Temp".
• If we want to change the units of the current reading, press "Unit ".
• To interrupt/continue measurement: Press each time.
• To end measurement and calculate the mean value: Press "Mean".
Mean
flashes. The calculated mean value in time is displayed.
•To return to measurement view: Press "Mean".
Holding the Displayed Readings
• Press "Hold/Zero" to freeze the readings on the display .The display shows HOLD.
• To change between displaying the temperature, flow velocity and calculated volumetric flow rate: Press
"Flow/Temp".
• Press "Hold/Zero" again to turn off the HOLD function.
Viewing the MIN, MAX Readings
• Press "Man/Mix" to step through the maximum (MAX), minimum (MIN), or the average (AVG) readings.
The elapsed time since entering MAX/ MIN mode, or the time at which the minimum or maximum
occurred appears on the display.
• Press "Man/Mix" button for 2 seconds to exit MAX/MIN mode.
Replacing the Batteries
• Turn off the thermometer if necessary.
• Loosen the screw and remove the battery door.
• Replace 9V batteries.
• Replace the battery door and tighten the screw.
8
All manuals and user guides at all-guides.com