Installation Manual
Protective Equipment Installed (bollards, wheel
stops, etc.)?
4. Electrical Information:
Voltage Type:
What is the total amperage of the
panel to which the charger is connec-
ted?
Is this panel dedicated just to your
Ford EV chargers?
Max Current Switch Setting, if appli-
cable (if your charger has a hard-
ware dip-switch, what is the current
setting?)
Electrical Information Specifics – circle in the table below or fill out in the last
column the breaker size, amp output rating, wire size for L1 and L2, wire size for
ground (GND), and wire coating.
Recommendations, need to comply with local AHJ. Choose or specify for each
row.
Breaker Size:
Amp Output
Rating:
Wire Size (L1 &
L2):
Wire Size (GND):
Wire Material:
Wire Coating:
Have all the wires been installed with the torque
specified in this manual?
Voltage Reading (L1 to GND): write in
Voltage Reading (L2 to GND): write in
Public
240V split-
phase
60
50
48
40
#6
#6
#8
#8
THHN, THWN-2, XHHW-2
37
48A Charging Station Series 2
208V th-
ree-phase
Yes
No
40
30
32
24
#8
#8
#10
#10
Copper
Yes
240V th-
ree-phase delta
Other
20
Specify:
16
Specify:
#10
Specify:
#12
Specify:
Copper
Specify:
No