48A Charging Station Series 2
If use flexible stranded wire with ferrule, make sure all wire strands are contained
in the ferrule.
Step 8.
Lock the conduit on the enclosure. Refer to the following torque.
Conduit
1 "
Step 9.
Fasten the copper wire on the corresponding terminal block. The wiring
instruction is printed in front of the terminal block (L1/L2/G).
Figure 4.11 Ferrule Use
35 kgf·cm
L 1 L1
Figure 4.12 Input Wiring Position
Torque
L2
L2
28
Installation Manual
30 lbf·in