1PH4 Tension réseau triphasée 400 V, Vector Control
Power
Magnetiz-
Efficiency
factor
ing current
η
I
μ
rated
cos ϕ
A
400 V 3 AC line voltage, Vector Control
0.75
11.5
0.841
0.78
13.5
0.854
0.78
18
0.867
0.82
12
0.887
0.79
22
0.901
0.81
23
0.905
0.78
42
0.914
0.80
44
0.920
0.82
43
0.921
Special versions:
Specify supplementary order code and plain text if applicable
(see Options).
Motor Module:
Single Motor Module
Double Motor Module
1)
n
: Max. permissible thermal speed at constant output or speed,
2
which is at the voltage limit when P = P
2)
n
: Max. permissible speed that is continuously permitted without
S1
speed duty cycles.
3)
n
: Maximum speed which must not be exceeded.
max
Moteurs asynchrones 1PH4
Manuel de configuration, (APH4S), 08/2008, 6SN1197-0AD64-0DP1
Rated
Moment of
Weight,
frequency
inertia of
approx.
f
J
rated
2
Hz
kgm
/
kg/lb
2
lb
-in-s
f
61.2
0.017/0.15
52/114.66
61.3
0.024/0.212
67/147.74
61.0
0.031/0.274
80/176.4
60.2
0.046/0.407
90/198.45
59.8
0.071/0.628
112/246.96
59.9
0.085/0.752
130/286.65
59.3
0.170/1.505
175/385.88
59.4
0.206/1.823
210/463.05
59.4
0.220/1.947
240/529.2
.
rated
1.4 Tableau de sélection et références de commande
1PH4 asynchronous
4)
motor 1PH4
Order No.
1PH4103- 4 . F 5 6
1PH4105- 4 . F 5 6
1PH4107- 4 . F 5 6
1PH4133- 4 . F 5 6
1PH4135- 4 . F 5 6
1PH4137- 4 . F 5 6
1PH4163- 4 . F 5 6
1PH4167- 4 . F 5 6
1PH4168- 4 . F 5 6
–Z
4)
Standard design with duplex bearing.
5)
The rated output current of the Motor Module is lower than the motor
rated current.
6)
Speed is limited to lower values in some cases. The following restriction
applies: Max. output frequency < 5 × motor rated frequency.
Description des moteurs
SINAMICS S120 Motor Module
Rated output current
I
rated
A
Order No.
5)
7
18
6SL3120-
T E21-8AA
30
6SL3120- 1 T E23-0AA 1
45
6SL3120- 1 T E24-5AA 1
45
6SL3120- 1 T E24-5AA 1
60
6SL3120- 1 T E26-0AA 1
5)
60
6SL3120- 1 T E26-0AA 1
5)
85
6SL3120- 1 T E28-5AA 1
132
6SL3120- 1 T E31-3AA 0
132
6SL3120- 1 T E31-3AA 0
1
2
7
1
0
21