The full face masks have been tested for use in explosion-hazard areas in
accordance with 2014/34/EU. The full face masks can be used in the following
zones:
–
Full face masks with PC visor
–
I M1
–
II 1 G IIB T6 -30 °C ≤ Ta ≤ +60 °C
–
II 1D
–
Full face masks with PCas or PCaf visor
–
I M1
–
II 1G IIC T6 -30 °C ≤ Ta ≤ +60 °C
–
II 1D
Mask/helmet combinations may only be used in hazardous areas with a water
screen.
3.6
Type-identical marking
The facepieces are marked differently:
Connector
RA, PE, ESA, P
Mask body
EPDM or Si,
EN 136:1998 CL 3+
CExxxx (notified body in Europe)
Mask body size
S (small), M (medium), L (large)
Inner mask size
1 (small), 2 (medium), 3 (large)
Visor
PC or APEC, F (fire brigade), according to EN 166
A (ballistic protection class 190m/s)
T (ballistic protection at extreme temperatures,
tested at -30 – +60 °C at 190 m/s)
PCas or APECas (coated with scratch-resistant
material on both sides)
Pcaf (coated with scratch-resistant material on the
outside, with anti-fog material on the inside)
Elastic straps
EPDM, CR or Si, M/L or S, H
Mask/helmet adapter
S-fix (H61) or Q-fix (H62) or X-fix
Instructions for use
|
Dräger FPS 7000
4
Use
4.1
Conditions for use
The mask/helmet combination needs to be carefully adapted to the equipment
wearer (correct mask size, fastening plate settings and internal helmet
components) due to its design. The mask/helmet adapter must be easy to
adjust.
The following conditions must be met if the full face masks are used with a
respiratory filter or a powered air-purifying respirator:
–
The ambient conditions (particularly the types and concentrations of
contaminants) must be known. Use corresponding respiratory filters. Only
use self-contained open-circuit breathing apparatus or air line breathing
apparatus in cases where the contaminant is unknown.
–
Only use filtering devices if the air does not directly endanger the health or
life of the user.
–
It must be ensured that the ambient atmosphere cannot change to the
worse.
–
Do not use filtering devices if there is suspicion of contaminants with low
warning properties (low-odour, tasteless, no irritation of eyes and airways).
A decreasing protective effect of the filtering device cannot be determined in
this case.
–
Do not use filtering devices for entering unventilated tanks, mines, canals,
etc.
–
Do not use filtering devices in oxygen-enriched atmospheres.
–
The oxygen content of the ambient air must not fall below the following limit
values:
–
at least 17 Vol% oxygen in all European countries except the
Netherlands, Belgium and UK
–
at least 19 Vol% oxygen in the Netherlands, Belgium, UK, Australia and
New Zealand
–
In other countries, observe the applicable national regulations.
4.2
Before first use
1. Remove the protective foil from the visor.
2. Check that the facepiece is leak-tight before using it for the first time (see
technical manual 9300767 at www.draeger.com/ifu).
|