en Installation instructions
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
The worktop must be secured to the fitted unit.
Observe any available installation instructions for the
hob.
Observe different national installation instructions for
the hob.
In order to ensure sufficient ventilation of the appliance,
there must be a ventilation opening of at least
100 cm². For example, trim the base panel or fit a vent-
ilation grille.
18.8 Installing below a hob
If the appliance is installed below a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The minimum worktop thickness
quired minimum clearance
Hob type
raised in
mm
Induction hob
45
Full-surface in-
55
duction hob
Gas hob
35
Electric hob
35
1
Observe different national installation instructions
for the hob.
Observe the installation instructions for the hob.
76
is based on the re-
⁠ .
flush in
in
mm
mm
46
5
56
5
1
46
5
38
2
18.9 Corner installation
Observe the installation dimensions and the safety
clearances when installing in a corner.
18.10 Installing the appliance
Centre the appliance.
1.
2.
Screw the appliance onto the unit.
18.11 For handleless kitchens with vertical
bar handle strips:
Attach a suitable filling piece on both sides in order
1.
to cover any sharp edges and to guarantee safe in-
stallation.
Secure the filling piece to the unit.