Télécharger Imprimer la page

CONSTRUCTA CC4W91963 Manuel D'utilisation Et Notice D'installation page 75

Publicité

Les langues disponibles

Les langues disponibles

When the appliance is installed, the mains plug of
the power cable must be freely accessible. If free
access to the mains plug is impossible, an all-pole
isolating switch must be integrated into the perman-
ent electrical installation in accordance with the in-
stallation regulations.
Electrically connecting an appliance without a
protective contact plug
Note: Only licensed specialists may connect the appli-
ance. Damage caused by incorrect connection is not
covered under the warranty.
An isolating switch must be integrated into the perman-
ent electrical installation according to the installation
regulations.
Identify the phase and neutral conductors in the
1.
socket.
The appliance may be damaged if it is not connec-
ted correctly.
See the rating plate for the voltage.
2.
Connect the wires of the mains power cable accord-
3.
ing to the colour coding:
Green/yellow = Protective conductor
Blue = Neutral conductor
Brown = Phase (external conductor)
18.4 Fitted units
This appliance is only intended to be fully fitted in a kit-
chen. It is not intended to be used as a tabletop appli-
ance or within a cupboard.
The installation cabinet must not have a back panel be-
hind the appliance. Maintain a clearance of at least
35 mm between the wall and the cabinet base or the
rear panel of the cabinet situated above.
The installation cabinet must have a ventilation opening
of 50 cm² on the front. To do this, trim the base panel
or fit a ventilation grille. Do not cover ventilation slots
and air intake openings.
18.5 Installation in a tall unit
Observe the installation dimensions and the safety
clearances in a tall unit.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
If the tall unit has another back panel in addition to the
element back panels, this must be removed.
Only install the appliance up to a height which allows
the accessory to be easily removed.
18.6 Installing two appliances on top of
each other
Your appliance can also be installed above or below
another appliance. Observe the installation dimensions
and the installation instructions when installing appli-
ances on top of each other.
To ventilate the appliances, the intermediate floor must
have a ventilation cut-out.
To ensure sufficient ventilation of the two appliances,
there must be a ventilation opening of at least 200 cm²
in the plinth area. To do this, trim the base panel or fit
a ventilation grille.
Ensure that air exchange is guaranteed in accordance
with the diagram.
Only install appliances up to a height that allows the
accessory to be easily removed.
18.7 Installation below a worktop
Observe the installation dimensions and the safety
clearances when installing below a worktop.
Installation instructions en