maximum fi lling quantity. Overfi lling the equipment may
result in damage. Reinsert the oil sealing plug (16) into
the oil fi ller opening (21).
10.6 Cleaning the intake filter (Fig. 3, 12, 13)
The intake fi lter prevents dust and dirt being drawn in.
It is essential to clean this fi lter after at least every 300
hours in service. A clogged intake fi lter will decrease
the compressor's performance dramatically. Open the
thumb screw (E) to the remove the intake filter.
Then pull off the fi lter cover (C). Now you can remove
the air fi lter (F) and the fi lter housing (D). Carefully tap
out the air fi lter, fi lter cover and fi lter housing. Then
blow out these parts with compressed air (approx. 3 bar)
and reinstall in reverse order.
10.7 Storage
n
Important!
Pull out the mains plug and ventilate the equipment
and all connected pneumatic tools. Switch off the
compressor and make sure that it is secured in
such a way that it cannot be started up again by any
unauthorized person.
n
Important!
12. Troubleshooting
Fault
Possible cause
The compressor does
• No supply voltage.
not start.
• Insuffi cient supply voltage.
• Outside temperature is too low.
• Motor is overheated.
The compressor starts
• The non-return valve leaks.
but there is no pressure.
• The seals are damaged.
• The drain plug for condensation water (9)
leaks.
The compressor starts,
• The hose connections have a leak.
pressure is shown on
the pressure gauge, but
• A quick-lock coupling has a leak.
the tools do not start.
• Insuffi cient pressure set on the pressure
regulator (3).
16
GB
Store the compressor only in a dry location which
is not accessible to unauthorized persons. Always
store upright, never tilted! Oil may leak out!
10.7.1 Releasing excess pressure
Release the excess pressure by switching off the com-
pressor and using the compressed air which is still left
in the pressure vessel, e.g. with a compressed air tool
running in idle mode or with a blow-out pistol.
11. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types of
material, such as metal and plastic. Defective compo-
nents must be disposed of as special waste. Ask your
dealer or your local council.
Remedy
• Check the supply voltage, the power plug and the
socket-outlet.
• Make sure that the extension cable is not too
long. Use an extension cable with large enough
wires.
• Never operate with an outside temperature of
below +5° C.
• Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
• Have a service center replace the non-return
valve.
• Check the seals and have any damaged seals
replaced by a service center.
• Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
• Check the compressed air hose and tools and
replace if necessary.
• Check the quick-lock coupling and replace if
necessary.
• Increase the set pressure with the pressure
regulator.