D.C. WELDING
Service
Welding current electronic regulation
Striking voltage
100
90
80
70
60
50
40
30
20
10
0
SIMULTANEOUS UTILIZATION FACTORS
In case Welding and Generation can be used simultaneously, however, the engine cannot be overloaded. The ta-
ble below gives the maximum limits to be respected:
WELDING CURRENT
AUXILIARY POWER
Technical data
350 A - 35%, 320 A - 60%, 270A - 100%
20 - 350 A
65 V
V (V)
50
100
350 A
OUTPUT CARACTERISTIC
WITH ARC FORCE (BC)
150
200
250
175 A
0
1.5 kVA
KHM 351 YS
I (A)
300
350
150 A
100 A
4 kVA
8 kVA
M
1.6
0
12 kVA