14. Troubleshooting
Fault
Possible cause
The compressor does not
No supply voltage.
start.
Insufficient supply voltage.
Outside temperature is too low.
Motor is overheated.
The compressor starts but
The safety valve (19) leaks.
there is no pressure.
The seals are damaged.
The drain plug for condensation water (10) leaks.
The compressor starts,
The hose connections have a leak.
pressure is shown on the
pressure gauge, but the
A quick-lock coupling has a leak.
tools do not start.
Insufficient pressure set on the pressure regulator
(5).
Remedy
Check the supply voltage, the power plug and the socket-
outlet.
Make sure that the extension cable is not too long. Use
an extension cable with large enough wires.
Never operate with an outside temperature of below
+5° C.
Allow the motor to cool down. If necessary, remedy the
cause of the overheating.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Check the seals and have any damaged seals replaced
by a service centre.
Tighten the screw by hand. Check the seal on the screw
and replace if necessary.
Check the compressed air hose and tools and replace if
necessary.
Contact your local service centre. Only allow qualified
personnel to carry out repairs.
Increase the set pressure with the pressure regulator.
GB/IE
19