DANGER
The device and packaging materials are not toys!
Children must not be allowed to play with plastic
bags, film and small parts! There is a risk of swal-
lowing and suffocation!
Before you connect the equipment to the mains supply, make
sure that the data on the rating plate are identical to the mains
data.
• Prior to initial commissioning, remove the transport lid (A)
and fill the compressor pump housing with oil as described
in item 9.4.
• Check the equipment for damage which may have occurred
in transit. Report any damage immediately to the transport
company which was used to deliver the compressor.
• Install the compressor near the point of consumption.
• Avoid long air lines and supply lines (extension cables).
• Make sure that the intake air is dry and dustfree.
• Do not install the compressor in a damp or wet room.
• The compressor may only be used in suitable rooms (with
good ventilation and an ambient temperature from +5 °C
to 40 °C). There must be no dust, acids, vapours, explosive
gases or inflammable gases in the room.
• The compressor is designed to be used in dry rooms. It is
prohibited to use the compressor in areas where work is con-
ducted with sprayed water.
• The oil level in the compressor pump has to be checked be-
fore putting the equipment into operation.
9. Assembly and operation
m Attention!
You must fully assemble the appliance before us-
ing it for the first time!
You will require the following tools for assembly:
1x Open-end spanner 13 mm
1x Phillips screwdriver
(not included)
9.1 Fitting the wheels (fig. 4)
• Fit the supplied wheels as shown.
9.2 Fitting the supporting feet (fig. 5)
• Fit the supplied supporting feet as shown.
9.3 Fitting the air filter (fig. 6, 7)
• Remove the transport lid (B) and screw the air filter (15) to
the equipment.
9.4 Changing the transportation lid (A) (fig. 8, 9)
• Remove the transport lid (A) of the oil filling opening (20).
• Fill the included compressor oil into the compressor pump
housing and insert the supplied oil sealing plug (16) into the
oil filling opening (20).
9.5 Mains connection
• The compressor is equipped with a mains cable with shock-
proof plug. This can be connected to any 220 - 240 V∼
50 Hz shock-proof socket.
16
GB/IE
• Before you use the machine, make sure that the mains volt-
age is the same as the operating voltage and the machine
power on the rating plate.
• Long supply cables, extensions, cable reels, etc. cause a
drop in voltage and can impede motor start-up.
• At low temperatures below +5°C, sluggishness may make
starting difficult or impossible.
9.6 ON/OFF switch (fig. 2)
• Pull the ON/OFF switch (17) upwards to switch on the com-
pressor. To switch off the compressor, press the ON/OFF
switch down.
9.7 Setting the pressure (fig. 1, 3)
• Use the pressure regulator (5) to set the pressure on the pres-
sure gauge (4).
• The set pressure can be drawn from the quick lock coupling
(3).
• The vessel pressure can be read off the pressure gauge (6).
• The vessel pressure is drawn from the quick-lock coupling
(7).
9.8 Setting the pressure switch (fig. 1)
• The pressure switch (2) is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar.
9.9 Fitting the compressed air hose (fig. 1, 3)
• Connect the nipple (H) on the compressed air hose (14) to
one of the quick-release couplings (3, 7). Then attach the
compressed air tool to the quick-release coupling (I) on the
compressed air hose (14).
9.10 Overload switch (fig. 13)
The motor is fitted with an overload switch (24). If the compres-
sor overloads, the overload switch switches off the equipment
automatically to protect the compressor from overheating. If
the overload switch triggers, switch off the compressor using
the ON/ OFF switch (17) and wait until the compressor cools
down. Then press the overload switch (24) and restart the com-
pressor.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
10.1 Important information
In the event of an overloading the motor will switch itself off. Af-
ter a cool-down period (time varies) the motor can be switched
back on again.