venting installation
EN
ADD FASTENER TYPE
4.3.3 appliance vent connection
A. Install the inner fl ex pipe to the appliance. Secure with a minimum of
three screws when installing 3"/5", 4"/7" or 5"/8" venting, or six screws
when installing 8"/10" or 8"/11" venting. Seal the joint and screw holes
using Mill Pac sealant (W573-0007) (not supplied).
B. Install the outer fl ex pipe to the appliance. Secure with a minimum of
three screws when installing 3"/5", 4"/7" or 5"/"8 venting, or six screws
when installing 8"/10" or 8"/11" venting. Seal the joints using high
temperature red RTV silicone (W573-0002) (not supplied).
4.3.4 horizontal air terminal installation
Move the appliance into position. Measure
A.
the vent length required between terminal and
appliance taking into account the additional
length needed for the fi nished wall surface and
any 2" (50.8mm) overlaps between venting
components.
B.
Apply a heavy bead of Mill Pac sealant
(W573-0007) (not supplied) to the outer edge of
the inner collar of the appliance. Attach the fi rst
inner rigid pipe component and secure using a
minimum of three screws. Repeat using the outer
rigid pipe. Seal using Red RTV Silicone (W573-0002)
(not supplied).
Insert the vent pipes through the fi restop maintaining the required clearance to
C.
combustibles. Apply a heavy bead of Red RTV Silicone (W573-0002) (not supplied) to both the
inner sleeve and outer sleeve of the air terminal. Slide the terminal sleeves into the rigid pipes a minimum
of 1 1/4". Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and
make weather tight by sealing with caulking (not supplied).
The air terminal mounting plate may be recessed into the exterior wall or siding no greater than the
depth of the return fl ange.
40
W415-4150 / A-0 / 05.23.24
REAR VENT
#8 X 1/2"
Self
Drilling
Mill Pac
Screws
Sealant
1 1/2"
(38.1mm)
Overlap
#10x2"
SCREWS
CAULKING
TOP VENT - FLEX
#8 X 1/2"
INSERT
Self Drilling
Screws
IMAGE HERE
2" (51mm)
1 1/4" (31.8mm)
Overlap
Mill-Pac Sealant
Red RTV
Silicone
19.1
INNER
RIGID
OUTER
PIPE
RIGID
PIPE
2" (50.8mm) OVERLAP
HI-TEMP
SEALANT
18.3A
#8 X
Self
Sc