Télécharger Imprimer la page

hajdu HB300C Manuel De Mise En Service, D'opération Et D'entretien page 81

Chauffee-eau thermodynamique

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 144
_________________________________ ___EN__________________________________33
E1
T5L sensor error.
E2
Communication error between the water tank and the wired controller
.
E4
Evaporation pipe temperature sensor error
E5
Ambient temperature sensor error.
E6
Compressor discharge pipe temperature sensor error
E7
Heat Pump system error
Leakage current error. If L, N> 14mA, the control indicates leakage
E8
current error.
T3 sensor – compressor discharge pipe sensor error
E9
EE
Electrical heater circuit not closed, broken wire
EF
Timer error, error of the timer control
Ed
E-EPROM chip error
P1
Overpressure protection error
P2
Discharge pipe overheating error
P3
No current flowing in the compressor
P4
Compressor overload error
The ambient temperature does not meet the operating conditions of
LA
the heat pump; the appliance switches to E-heater mode
automatically
Remark:
If you perceive defective operation of the appliance, please turn to either a contracted
service shop or our to our customer service.
Control panel
Water tank
Table 4.5.-1.
Electric heating
Compressor
Pressure switch
Compressor
T3: Pipe temperature sensor
T4: Environmental temperature
sensor
T5L: Tank temperature sensor
(lower)
TSU: Tank temperature sensor
(upper)
TP: Discharge temperature sensor
TH: Air reflow temperature sensor

Publicité

loading

Ce manuel est également adapté pour:

Hb300Hb300c1Hb 200c