The error messages are displayed in a pop-up on the
Purion 200 control unit.
The operating unit shows whether critical errors or
less critical errors occur on the eBike.
The error messages generated by the eBike can be
read via the eBike Flow app or by your bicycle re-
tailer.
Via a link in the eBike Flow app, information about
the error and support for rectifying the error can be
displayed.
Less critical errors
Errors are acknowledged by pressing the select but-
ton (4).
You can use the following table to rectify the errors
yourself if necessary. Otherwise, please contact your
bicycle retailer.
Number
Troubleshooting
523005
The indicated error numbers show that
there is interference when the sensors
514001
detect the magnetic field. See whether
514002
you have lost the magnet while riding.
514003
If you are using a magnet sensor, check
514006
that the sensor and magnet have been
properly installed. Make sure too that
the cable to the sensor is not damaged.
If you are using a rim magnet, make
sure that you do not have any magnetic
field interference in the vicinity of the
drive unit.
680007
The indicated error numbers show that
the eBike battery is outside of the per-
680009
missible operating temperature. The
680012
charging of the eBike battery is inter-
680014
rupted.
680016
As soon as the operating temperature
680017
returns to the permissible range, the
charging process will start again.
Bosch eBike Systems
Troubleshooting
Critical errors
If a critical error occurs, follow the handling instruc-
tions on the following table.
Number
6A0004
890000
Handling instructions
Remove the PowerMore battery and
restart your eBike.
If the problem persists, please contact
your specialist retailer.
– Acknowledge the error code.
– Restart the eBike system.
If the problem persists:
– Acknowledge the error code.
– Perform the software update.
– Restart the eBike system.
If the problem persists:
– Please contact a Bosch eBike sys-
tems specialist retailer.
0 275 U07 3RP | (03.05.2024)